O.W.S. Analyzer — 15 PPM Testing & Calibration

Professional Onboard Oily Water Separator Analyzer Testing, Calibration and Maintenance

Kraken Marine Electric provides professional O.W.S. analyzer testing and calibration services for onboard Oily Water Separator systems. We also service 15 ppm bilge alarm monitoring equipment.

The Oily Water Separator is one of the most important pollution prevention systems onboard vessels. Accurate analyzer performance and reliable 15 ppm alarm operation are essential for safe bilge water treatment and environmental protection. In addition, these are required for compliance with applicable MARPOL requirements. Regular OWS analyzer calibration, testing and maintenance helps vessel operators verify that the system operates correctly. This also reduces the risk of improper discharge, non-compliance and operational failure.

Our service covers inspection, functional testing, calibration, alarm verification, control output checks, maintenance and documentation for O.W.S. analyzers. It also covers related monitoring equipment.


Our O.W.S. Analyzer Testing and Calibration Service

Kraken Marine Electric performs onboard Oily Water Separator analyzer calibration using professional procedures. These are in accordance with manufacturer recommendations and applicable marine environmental standards.

Our O.W.S. analyzer service scope includes:

  • O.W.S. analyzer inspection
  • 15 ppm bilge alarm testing
  • 15 ppm alarm point verification
  • Analyzer calibration
  • Zero and span check where applicable
  • Clean water response check
  • Sample water line inspection
  • Measuring cell inspection and cleaning
  • Optical sensor / measuring chamber inspection where applicable
  • Alarm output function test
  • Automatic stopping device / three-way valve signal check where applicable
  • Control relay output verification
  • System functional test
  • O.W.S. monitoring equipment inspection
  • Fault diagnosis and troubleshooting
  • Preventive maintenance
  • Service report and calibration certificate

All tests can be performed onboard, at shipyards, ports This depends on vessel availability and operational conditions.


Why O.W.S. Analyzer Calibration Is Essential

The 15 ppm bilge alarm is designed to monitor oil content in treated bilge water. It will activate alarm or control functions when the oil concentration exceeds the permitted limit. If the analyzer is not correctly tested, calibrated or maintained, the vessel may face inaccurate readings or false alarms. There is also the risk of failed alarm activation or improper discharge.

Regular Oily Water Separator calibration helps ensure that the analyzer gives accurate readings. Furthermore, alarm and control functions will operate reliably during vessel operation.

Professional O.W.S. analyzer testing can identify issues such as:

  • Incorrect ppm reading
  • Analyzer drift
  • Contaminated measuring cell
  • Dirty optical surfaces
  • Blocked or restricted sample lines
  • Faulty alarm output
  • Defective control relay
  • Failure of automatic stopping function
  • Incorrect zero or span response
  • Unstable measurement
  • Sensor or electronic faults
  • Poor maintenance condition
  • Risk of non-compliant operation

Early detection and correction of these faults improves the reliability of the O.W.S. system. As a result, it supports safe, compliant vessel operation.


15 PPM Bilge Alarm Testing

The 15 ppm bilge alarm test is a critical part of O.W.S. analyzer maintenance. During testing, the analyzer response, alarm activation and related control outputs are checked. This verifies correct operation.

Depending on the system configuration, our technicians can check the alarm function and control relay operation. They also check the automatic stopping signal and associated monitoring circuits. This ensures that the analyzer not only displays a reading, but also performs its required safety and environmental protection functions.

Reliable 15 ppm alarm performance helps protect:

  • The vessel
  • The crew
  • The marine environment
  • Shipowners and managers
  • Compliance records
  • Port State Control readiness
  • Long-term operational reliability

Oily Water Separator Maintenance and Fault Diagnosis

In addition to calibration and testing, Kraken Marine Electric provides Oily Water Separator analyzer maintenance and troubleshooting. Many O.W.S. analyzer problems are caused by contamination, poor sample flow or dirty measuring cells. In some cases, aging components or incorrect system response are responsible.

Our technicians inspect the analyzer and related monitoring equipment to identify technical issues affecting measurement accuracy or alarm reliability. Where required, cleaning, adjustment, fault diagnosis and corrective recommendations are provided.

Our goal is to help vessels maintain accurate analyzer performance. We also aim for dependable O.W.S. operation under real marine conditions.


Supported O.W.S. Analyzer Brands and Models

Kraken Marine Electric supports testing, calibration and maintenance for all major O.W.S. analyzer and 15 ppm bilge alarm brands and models. This includes but is not limited to:

  • Deckma Hamburg
  • Rivertrace
  • Brannstrom
  • RWO
  • JOWA
  • Other marine O.W.S. analyzer systems

Whether the vessel is equipped with an older 15 ppm bilge alarm or a modern monitoring unit, our team can perform the required onboard inspection and testing. They also handle calibration procedures.


MARPOL Compliance and Environmental Safety

Oily Water Separator systems play a key role in marine pollution prevention. Reliable analyzer operation supports compliance with applicable MARPOL requirements and helps prevent the discharge of oily water above permitted limits.

A properly tested and calibrated O.W.S. analyzer helps vessel operators maintain:

  • Environmental compliance
  • Accurate bilge water monitoring
  • Reliable alarm and control functions
  • Proper system documentation
  • Reduced risk of improper discharge
  • Improved inspection readiness
  • Safer and more responsible vessel operation

Kraken Marine Electric provides O.W.S. analyzer services with a strong focus on accuracy and reliability. We also stress documentation and environmental responsibility.


Quality-Focused Calibration and Documentation

Kraken Marine Electric delivers OWS analyzer calibration and testing services with a quality-oriented service approach. Each service is carried out carefully, with attention to manufacturer procedures and technical accuracy. Clear documentation is always provided.

Our quality approach includes:

  • Professional onboard service procedures
  • Manufacturer-based testing and calibration practices
  • Accurate functional checks
  • Detailed inspection records
  • Clear reporting of findings
  • Practical recommendations for corrective action
  • Calibration and service documentation
  • Technical support for marine pollution prevention systems

We understand that O.W.S. analyzer reliability is directly connected to environmental safety and vessel compliance. For this reason, our service process is designed to support dependable system operation. It also aims for long-term equipment performance.


O.W.S. Analyzer Calibration Certificate and Service Report

After completion of the service, Kraken Marine Electric can provide a detailed O.W.S. analyzer calibration certificate and service report. This includes equipment details, test results, calibration status, alarm function verification, detected issues and maintenance actions performed.

This documentation supports vessel planned maintenance systems, technical records, environmental inspections and internal audits. In addition, it supports class or Port State Control follow-up when required.


Professional Onboard O.W.S. Analyzer Calibration Service

Kraken Marine Electric supports vessels with reliable, efficient and professional onboard O.W.S. analyzer testing and calibration services. Our services are suitable for planned maintenance, annual inspections, dry dock periods, troubleshooting cases and environmental compliance preparation.

For accurate 15 ppm monitoring, reliable alarm operation and safe Oily Water Separator performance, regular analyzer testing and calibration is an essential part of responsible vessel maintenance.

Contact Kraken Marine Electric for professional O.W.S. analyzer calibration, 15 ppm bilge alarm testing, Oily Water Separator maintenance and onboard marine environmental compliance services.

Click here to contact us